SPD Overcurrent Protection: Your Decision. Our Provision.

Oct 17
4 min read

The updated Navitas MX consumer unit gives contractors the flexibility to add dedicated SPD overcurrent protection, with the practical details already considered.

You assess the installation. You understand the project requirements. You make the decisions that shape the finished job.


At Navitas, we believe your consumer unit should support that process.

Our updated MX range uses a single module surge protection device, without a dedicated SPD MCB fitted as standard. But changing the standard arrangement hasn’t removed your option to incorporate one.


We’ve retained that provision and considered how it works inside the board.

We haven’t made that decision for you. We’ve made provision for your decision.


Watch: adding dedicated SPD overcurrent protection

In this video, William demonstrates how the updated MX board accommodates dedicated SPD protection, including the device arrangement, conductor routing and provision for repositioning the meter tail clamp.


adding OCp to your SPD with the new Navitas MX series

Contractor choice should be reflected in the product

Electricians have different approaches to SPD overcurrent protection. Projects also bring different specifications, installation requirements and practical considerations.

If your decision is to incorporate a dedicated MCB for the SPD, the board should provide a clear arrangement for doing so.


That means considering more than whether another device will physically fit.

Where will the SPD sit? How will the conductor reach its connection? Will the meter tail clamp accommodate the revised layout?


These are product design questions. We’ve worked through them so you can see how the arrangement comes together before you get to site.


The flexibility is in the details

An adaptable device arrangement

The updated MX board accommodates the repositioning of the main switch and SPD to incorporate the dedicated MCB arrangement shown in our video.


This gives contractors a defined configuration to follow, supported by the accompanying installation guide.


The option forms part of the product design.


A supplied conductor with the route considered

The board includes a line conductor long enough to follow the route demonstrated around the incoming meter tails.


That provision supports an organised layout when dedicated SPD overcurrent protection is added. The connection route has been considered alongside the device positions, rather than left as a separate problem for the installer.


A meter tail clamp that can be repositioned

Moving the SPD also means considering the components beside it.

An additional pilot hole allows the meter tail clamp to be repositioned to suit the revised arrangement.


It is a small feature with a practical purpose: accommodating the change you want to make without overlooking the hardware around it.


That is what useful flexibility looks like. The details work together to support your decision.


Designed to accommodate dedicated SPD protection

BS 7671 Regulation 534.4.5.1 requires SPD installations to be protected against short circuit currents, with the protection arrangement taking account of the manufacturer’s instructions. electrical.theiet.org

At Navitas, we recognise that contractors assess the protection arrangement for the installation in front of them.


If your decision is to include dedicated SPD overcurrent protection within the consumer unit, we’ve designed the updated MX board to accommodate it.


The device layout, supplied conductor and provision for repositioning the meter tail clamp make that option practical.

Use the specified arrangement and installation instructions when configuring the board.


Contractor first means listening, then acting

The people fitting our products see the details that matter on site.

Their feedback comes through conversations with our team, social media, trade shows and wholesaler counters. Those conversations help shape the next product improvement.


Sometimes the result is an adaptable protection arrangement. Sometimes it is a change to a screw or mounting position.


In the OCP video, William also highlights longer lid screws with larger heads, making the lid easier to fit and remove. He demonstrates the provision for a left hand main switch arrangement too.


Each improvement addresses a practical part of working with the board.

For us, contractor first means listening to how you work and turning that feedback into something you can use.


See the arrangement before you plan the installation

Knowing how a product can be configured helps you decide whether it suits the job.

The video lets you see the components and understand how they are repositioned. The illustrated guide provides the installation information to accompany that demonstration.


Together, they help you review the arrangement before work begins.


Our OCP Installation Guide for MX Boards covers:

  • The revised device layout.

  • Connection points and installation sequence.

  • Terminal torque settings.

  • Final installation checks.


Your decision. Our provision.

Moving to a single module SPD hasn’t changed our approach to contractor choice.

We’ve retained the ability to add dedicated SPD overcurrent protection and considered the surrounding details needed to accommodate it.


You can see the provision in the product, understand it through the demonstration and follow it through the supporting guide.


You make the installation decisions. We design products that help you carry them out.





Based in Pencoed, South Wales, Navitas supports electricians across the UK. For questions about the updated MX arrangement, contact info@navitascp.co.uk or 01656 488004.


NAVITAS. INTELLIGENT REBELLION.


Frequently asked questions


Can I add dedicated SPD overcurrent protection to the updated Navitas MX consumer unit?

Yes. The updated MX design accommodates the dedicated MCB arrangement demonstrated in our video. Follow the MX OCP installation guide for the specified device, connections and installation requirements.


What provision is included for adding a dedicated SPD MCB?

The design includes an adaptable device arrangement, a supplied line conductor for the optional MCB configuration and an additional pilot hole for repositioning the meter tail clamp.


Why has Navitas retained this flexibility?

We recognise that contractors assess the requirements of their projects and make decisions about the protection arrangement. Our design accommodates the addition of dedicated SPD overcurrent protection when that arrangement is selected.


Where can I find the MX OCP installation instructions?

The illustrated OCP Installation Guide for MX Boards is available on the Navitas website. It provides the layout, connection information, terminal torque settings and final checks to accompany the video.